EQUIPMENTS
|
Home | Overview | Objectives | Research team | |
Equipments | Partners | Sites | Calendar | Results | Data | ||
1. DELTA V Advantage Isotope Ratio Mass Spectrometer produced by Thermo Finnigan |
Its sensitivity for CO2 in Dual Inlet mode is better than 1200 molecules per ion. The standard collectr configuration is the Universal Triple Collector. The DELTA V Advantage delivers high performance in Dual Inlet and Continuous Flow mode. Excellent linearity is guaranteed with or without helium carrier gas flow. Sensitivity Dual Inlet mode Molecules CO2 / mass 44 ion: 1200 M/l Sensitivity Continuous Flow mode Molecules CO2 / mass 44 ion: 1500 M/l Isotope Ratio Linearity: 0.02 0/00 nA Mass range at 3 kV: 1 - 80 Dalton Effective Magnetic Deflection Radius: 191 mm Noise level: < 50 dB(A) |
![]() |
2. Atlas M-86 mass spectrometer type designed by Varian MAT, Bremen |
Sensitivity Dual Inlet mode: 0.03% Sensitivity Continuous Flow mode: 0.5% Isotope Ratio Linearity: < 1‰ Mass range at 3 kV: 1- 100 Dalton Effective Magnetic Deflection Radius: 100 mm Noise level: < 10-6 |
![]() |
3. SMAD-1 mass spectrometer for hydrogen isotope analysis, home made in N.I.R.D.I.M.T Cluj-Napoca |
Isotope concentrations domain: 100 - 10.000 ppm Sensitivity: 4.5 x 10-8 (A/Pa) Base error for the concentration domain: |
![]() |
4. Off line extraction devices |
- extraction of carbon, nitrogen and water from organic matter by combustion |
![]() |
5. EGM-4 Environmental Gas Monitor for CO2 |
Analysis Method: Non-dispersive infrared, configured as an absolute absorptiometer with microprocessor control of liniarisation Measurement Range: CO2: 0 - 2.000 ppm(µmol mol-1). Measurements are automatically corrected for temperature and pressure. Accuracy (CO2): Better than 1% (limited by calibration gas mixture) Linearity: Better than 1% throughout the range Housing: High impact, aluminium enclosure Dimensions: 18 cm (W) x 21.5 cm (H) x 6.3 cm (D) mm Weight:1.5 kg (including battery) |
![]() |
6. Shaking Water Bath |
Overall dimensions (wxdxh): 715x520x330 mm Inside dimensions (wxdxh): 450x300x160 mm Working height: 190 mm Temperature range with level regulator: approx. 30oC above tap water temperature to 99.9oC Shaking motion: reciprocating Shaking frequency: 10 - 250 min-1 |
![]() |
7. Electronic Precision Balance EG 420-3NM Analytical Balance Metter |
Readout: 0.001 g Weighing range (max): 420 g Class of accuracy: II Adjusting weight: internal |
![]() |
8. Device for the enrichment of tritium by electrolysis |
Batch of 10 electrolysis cells.The cell batch is controlled by a pre-programmable electronic system that interrupts the current through any cell when the desired electrolyte volume is attained. |
![]() |
9. Furnace for the combustion of the organic samples |
The method: Dumas combustion with temperature controller tmax = 10000C |
![]() |
10. Distillation apparatus |
Distillation column filled with metal. |
![]() ![]() |